MULTIMETER CLAMP METER MAX 2000 AMP

https://adwaa-al-jazeerah-trading-est.odoo.com/web/image/product.template/46241/image_1920?unique=97017f7

Wide current measurements with tear drop type 55mmφCT up to 2000A.
Data-hold and Auto power off function.
Additional AC/DC voltage, resistance, diode test, continuity check.
Conform to IEC safety requirements.

Safety standard IEC 61010-1, IEC 61010-2-032 Installation CategoryⅡ600V or CategoryⅢ300V.
E.M.C. standard IEC 61326
Measuring method Dual slope integration mode
Display 3.5 digit LCD, max. reading of 1999
Jaw opening capability 55mmφ
Over range indication Blanking of all digits except MSD 1
Low battery indication "Battery" mark on LCD
Data hold indication "DH" mark on LCD
Sampling 2 times/sec
Withstanding voltage AC 3700V 1 minute max. (Between the core of CT and outer case)
Operating temperature 0℃ to 40℃, 80%RH max. ( Without condensation )
Storage temperature -10℃ to 60℃, 70%RH max. ( Without condensation )
Power supply 1.5V (AM-4, LR03 or AAA)×2
Power consumption 3.5mW
Auto power off Approx. 10 minutes later after power on
Battery life Approx. 500 hours continuous
Size 85(W)×240(H)×34(D)mm
Weight Approx. 350g
Accessories Hard carrying case
Instruction manual
Test lead
Batteries
Accuracy
Function Range Accuracy Maximum input
AC A (50/60Hz)
Manual ranging 20A ±1.2% rdg ±10 dgt AC2000A
(30 second)
200A ±1.2% rdg ±10dgt
2000A ±1.2% rdg ± 8 dgt
AC V (50/60Hz)
DC V
Auto ranging 2V ±0.7% rdg ± 5 dgt DC 750V
or
AC 750V rms
20V ±1.2% rdg ± 5 dgt
200V ±1.2% rdg ± 5 dgt
750V ±1.2% rdg ± 5 dgt
Resistance(Ω)
Auto ranging 200Ω ±1.2% rdg ± 5 dgt Input protection
250V rms
(30 second)
2kΩ ±1.2% rdg ± 5 dgt
20kΩ ±1.2% rdg ± 5 dgt
200kΩ ±1.2% rdg ± 5 dgt
2000kΩ ±1.2% rdg ± 5 dgt
20MΩ ±3.0% rdg ±10 dgt
Continuity check 2kΩ Beeper <approx.300Ω 250V rms
Diode test 2V ±10% rdg ± 3dgt 250V rms

550.00 SR 550.0 SAR 550.00 SR

550.00 SR

Not Available For Sale

This combination does not exist.

Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days