MULTI DIGITEL CLAMP METER MAX 600 AMP
Data-hold and Auto power off function.
Conform to IEC safety requirements.
Additional AC/DC voltage, resistance, diode test, continuity check.
Withstanding Voltage AC 5500V 1 minute max. (Between the core of CT and outer case)
Storage Temperature -10℃ to 60℃, 70%RH max. ( Without condensation )
Accuracy (23℃±5℃, 80%RH or less)
Function/Range/Accuracy/Maximum input
AC A (50/60Hz) Manual ranging/20A/±1.2% rdg ±10 dgt/AC600A
AC A (50/60Hz) Manual ranging/200A/±1.2% rdg ±10dgt/AC600A
AC A (50/60Hz) Manual ranging/600A/±1.0% rdg ± 8 dgt/AC600A
AC V (50/60Hz) DC V Auto ranging/2V/±0.7% rdg ± 5 dgt/DC 600V or AC 600V rms
AC V (50/60Hz) DC V Auto ranging/20V/±1.2% rdg ± 5 dgt/DC 600V or AC 600V rms
AC V (50/60Hz) DC V Auto ranging/200V/±1.2% rdg ± 5 dgt/DC 600V or AC 600V rms
AC V (50/60Hz) DC V Auto ranging/600V/±1.2% rdg ± 5 dgt/DC 600V or AC 600V rms
Resistance(Ω) Auto ranging/200Ω/±1.2% rdg ± 5 dgt/Input protection 250V rms (30 second)
Resistance(Ω) Auto ranging/2kΩ/±1.2% rdg ± 5 dgt/Input protection 250V rms (30 second)
Resistance(Ω) Auto ranging/20kΩ/±1.2% rdg ± 5 dgt/Input protection 250V rms (30 second)
Resistance(Ω) Auto ranging/200kΩ/±1.2% rdg ± 5 dgt/Input protection 250V rms (30 second)
Resistance(Ω) Auto ranging/2000kΩ/±1.2% rdg ± 5 dgt/Input protection 250V rms (30 second)
Resistance(Ω) Auto ranging/20MΩ/±3.0% rdg ±10 dgt/Input protection 250V rms (30 second)
Continuity check/2kΩ/Beeper < Approx. 300Ω/250V rms
Diode test/2V/±10% rdg ± 3dgt/250V rms
Operating Temperature 0℃ to 40℃, 80%RH max. ( Without condensation )
Power supply 1.5V (AM-4, LR03 or AAA)×2
Power consumption 3.5mW
Weight Approx. 425g
Safety standard IEC 61010-1, IEC 61010-2-032
Installation CategoryⅢ600V phase to earth
Jaw opening capability 40mmφ
Size 70(W)×223(H)×34(D)mm
Accessories Hard carrying case:1
Instruction manual:1
Test lead:1set
Batteries:2
Display 3.5 digit LCD, max. reading of 1999
Over range indication Blanking of all digits except MSD 1
Data hold indication "DH" mark on LCD
Low battery indication "Battery" mark on LCD
Auto power off Approx. 10 minutes later after power on
E.M.C. standard EN 61326
Measuring method Dual slope integration mode
Battery life Approx. 500 hours continuous
Sampling 2 times/sec